    Analyzer Sample Lines

    An analyser is only as accurate as the sample that reaches it. Heated and pre-insulated sample lines carry gas and liquid samples from the process tap to CEMS, process analysers and gas chromatographs while holding them at a controlled temperature, so the sample does not condense, adsorb or thicken on the way. Techwin builds these lines as factory-assembled Traceline bundles.

    Why sample lines are heated

    Stay above the dew point

    If a gas sample cools below its dew point, water condenses in the line. Soluble components dissolve in that water, so the analyser reads less than is really in the process.

    Prevent adsorption

    Reactive and sticky components — sulphur compounds, mercury, ammonia, some VOCs — can cling to cold or untreated tube walls, delaying and lowering the reading.

    Keep liquids flowing

    Liquid samples can thicken or freeze in cold weather. Holding the line at temperature keeps viscosity and transport time steady.

    Protect people

    Insulation and an outer jacket keep the surface of a hot line safe to touch. Techwin bundles keep the outer jacket below 60°C.

    Choosing how the line is heated

    Electrical heat traced sample lines

    The usual choice for analyser shelters, stacks and long runs. Self-regulating cables cover about 40°C, 110°C and 120–150°C maintain ranges; constant-wattage cable maintains up to 200°C; power-limiting circuits run up to 450 m.

    Specifications

    Steam traced sample lines

    For plants with steam available and high-temperature sampling. Heavy steam traced bundles maintain process temperatures over 204°C without an electrical supply in the field.

    Specifications

    Pre-insulated sample lines

    For short, low-heat-loss runs where the sample only needs protection from the weather, not active heating.

    Specifications

    New to tracing? Read the heat traced tubing buyer guide.

    What to specify

    • Sample dew point and the temperature the analyser needs the sample delivered at
    • Components to be measured — and whether any are reactive or prone to adsorption
    • Line length from the sample point to the analyser
    • Heat source available on site — power or steam
    • Hazardous-area classification at the sample point and along the route
    • Number and size of tubes (sample, return, calibration gas) and their material

    Typical Traceline sample line bundles use one or two process tubes of 1/8″–3/4″ or 6–12 mm OD, fibre-glass or aerogel insulation, and an FR-PVC, TPE, TPU or PA outer jacket.

    Where Techwin sample lines are used

    • Continuous emissions monitoring systems (CEMS)
    • Process analysers
    • Gas chromatographs
    • Instrument sample lines to flow, pressure and level transmitters

    Customers named in the Techwin company profile include analyser and instrumentation companies such as ABB, Yokogawa, Emerson, SICK, Thermo Fisher and Horiba.

    Frequently asked questions

    What is a heated sample line?

    A heated sample line is a tube bundle that carries a gas or liquid sample from the process to an analyser while a heating cable or steam tracer keeps it at a set temperature. Insulation and an outer jacket hold the heat in and protect the line.

    Why do CEMS and process analyser sample lines need heating?

    Samples carried to CEMS and process analysers are susceptible to condensation, adsorption and changes in viscosity. Keeping the line above the sample dew point stops water condensing and taking soluble components out of the gas, so the analyser measures what is really in the process.

    Which tube material should I use for an analyser sample line?

    Stainless steel 316 suits most samples. PTFE, FEP or PFA suit corrosive samples. For trace sulphur, mercury, ammonia or VOC analysis, a SilcoTek SilcoNert coated tube stops the sample adsorbing on the tube wall; electropolished 316L gives a very smooth, clean surface and is the recommended base for coating.

    How long can a heated sample line be?

    It depends on the heating cable. In Techwin bundles, power-limiting cable allows circuits up to 450 m, while constant-wattage and self-regulating cables are used on shorter runs. Long lines also increase transport time, which affects analyser response.

    Can heated sample lines be used in hazardous areas?

    Yes, when the heating cable is certified for the area. The heating cables used in Techwin electrical traced tubing carry IECEx, ATEX and IEC hazardous-area certification.

    Specify a sample line

    Send the analyser, sample composition, dew point, line length and area classification, and our engineers will propose a bundle.