Skip to main content

    العربية

    Middle East · GCC

    Heat Traced Tubing Bundles for the Middle East

    Techwin International manufactures factory-assembled electrical heat traced, steam traced and pre-insulated tubing bundles for analyser sample lines and process instrumentation, and is an ADNOC approved vendor and the authorised SilcoTek® distributor for the Middle East.

    • United Arab Emirates
    • Saudi Arabia
    • Oman
    • Qatar
    • Kuwait
    • Bahrain

    Approvals and credentials

    ADNOC approved vendor

    Techwin International is an approved vendor to ADNOC (Abu Dhabi National Oil Company).

    Authorised SilcoTek® distributor

    Techwin is the authorised SilcoTek® distributor for the Middle East and India — Silcolloy®, SilcoNert®, Dursan® and Siltride® coatings.

    Hazardous-area heating cables

    The heating cables in Techwin electrical traced bundles carry IECEx, ATEX and IEC hazardous-area certification.

    Factory-assembled bundles

    Tube, tracer, insulation and jacket are built into one bundle in our own factory in Bhiwandi, near Mumbai, and shipped ready to install.

    Why Gulf plants still trace their lines

    Heat tracing in the Middle East is about holding a sample or fluid at a set temperature, not about keeping out the cold.

    Hot ambient does not keep a sample warm enough

    Stack gas, sour gas and many process samples have dew points well above even a Gulf summer ambient. The line still has to be held above that dew point, or water condenses and takes soluble components with it.

    Air-conditioned analyser shelters

    Sample lines entering a cooled shelter drop in temperature over the last few metres. Tracing has to continue to the analyser inlet.

    Cold nights and winter

    Desert and inland sites can see large day–night swings and winter lows that thicken heavy liquids, sulphur and fuel oil in untraced lines.

    Sun, sand and UV

    Outdoor runs need a UV-resistant outer jacket and sealed ends. Techwin bundles use FR-PVC, TPE, TPU or PA jackets selected for the site conditions.

    Bundles for gas processing, LNG, refining and petrochemicals

    Electrical heat traced tubing

    Analyser sample lines and instrument impulse lines in gas processing, LNG and refining. Self-regulating cables cover about 40°C (104°F), 110°C (230°F) and 120–150°C (248–302°F); constant-wattage maintains up to 200°C (392°F); power-limiting circuits run up to 450 m (1,475 ft).

    Specifications

    Steam traced tubing

    Where plant steam is available: sulphur recovery, bitumen and heavy-oil service. Saturated steam up to 17 bar / 246 psi (204°C / 399°F).

    Specifications

    Pre-insulated tubing

    Weather and sun protection for lines that need insulation but no active heating.

    Specifications

    SilcoTek® coated tubing

    SilcoNert® inert coatings stop sulphur compounds such as H₂S and mercaptans adsorbing on the tube wall — the key problem when sampling sour gas for trace analysis.

    Specifications

    See also the heat traced tubing buyer guide and analyzer sample lines.

    What to send with a Middle East enquiry

    • Project, end user and applicable company specification (e.g. ADNOC)
    • Sample or process fluid, and the temperature it must be held at
    • Minimum and maximum site ambient, and whether the run is in direct sun
    • Line length and number, size and material of tubes
    • Heat source on site — power or steam
    • Hazardous-area classification along the route

    Frequently asked questions

    Is Techwin an ADNOC approved vendor?

    Yes. Techwin International, the Indian manufacturer of heat traced and pre-insulated tubing bundles, is an ADNOC approved vendor.

    Who is the SilcoTek distributor for the Middle East?

    Techwin International is the authorised SilcoTek® distributor for the Middle East and India, supplying Silcolloy®, SilcoNert®, Dursan® and Siltride® coated tubing, fittings and components. SilcoTek lists Techwin on its own website.

    Why do sample lines need heat tracing in a hot climate?

    Because what matters is the sample dew point, not the weather. Many gas samples have dew points above the highest ambient temperature, and lines cool where they enter air-conditioned analyser shelters or at night. Without tracing, water condenses in the line and the analyser under-reads.

    Can Techwin heat traced bundles be used in hazardous areas in the Gulf?

    The heating cables used in Techwin electrical traced bundles carry IECEx, ATEX and IEC hazardous-area certification. Give the zone classification and gas group when you ask for a quote so the right cable is selected.

    Which countries in the Middle East does Techwin supply?

    Our global sales desk handles enquiries from the United Arab Emirates, Saudi Arabia, Oman, Qatar, Kuwait and Bahrain. Bundles are manufactured in Bhiwandi, India, and shipped to site. Write to sales.global@techwin.in.

    Quote for a GCC project

    Send the project, specification and line list to sales.global@techwin.in or use the form.

    Request a quote