    Tubing Bundle Data Sheet: What to Specify for a Quote

    A heat traced or pre-insulated tubing bundle is built for one duty, so the quotation is only as good as the data behind it. This checklist lists every item Techwin International needs to design an electrical traced, steam traced or pre-insulated bundle, and why each one matters. Fill in what you know; anything left blank is agreed with our engineers before the design is fixed.

    Request a quote

    1. Process tubes and fluid

    ItemWhat to giveWhy it matters
    Number of process tubesOne, two or more tubes in the same bundleSets the bundle diameter, the heat load and the bend radius
    Tube outside diameter and wallImperial (1/8″–3/4″) or metric (6–12 mm), with wall thicknessMust match the fittings at the tap and at the analyser or transmitter
    Tube materialSS 316/316L seamless or welded, copper, PTFE, FEP or PFADecided by the fluid, the pressure and the sample purity needed
    Fluid and phaseGas, vapour or liquid; composition; dew point or freezing point if knownSets the lowest temperature the line must hold
    Design pressureNormal and maximum pressure in the tubeConfirms the tube material and wall thickness

    2. Temperatures

    ItemWhat to giveWhy it matters
    Maintain temperatureThe temperature the fluid must stay at or above, in °C or °FSelects the heat source and, for electric bundles, the cable type
    Maximum exposure temperatureThe hottest condition the line can see, including steam-out or purgeThe cable and insulation must survive it without damage
    Lowest and highest ambient temperatureSite design minimum and maximum, and wind exposure if knownSets the heat loss the bundle must replace
    Personnel protectionWhether the outer jacket must stay below a touch-safe temperatureAffects insulation thickness and type

    3a. Electrical traced bundles

    • Supply voltage at site
    • Length of each circuit, or the route length from power point to end
    • Cable preference, if any: constant wattage, self-regulating or power limiting
    • Temperature control and monitoring wanted (thermostat, controller, sensor)
    • Power connection, splice and end-seal kits required

    3b. Steam traced bundles

    • Steam pressure and temperature available
    • Heavy tracing (tracer touching the tube) or light tracing (separated)
    • Tracer material and size: copper or stainless steel
    • Where condensate will be removed along the route
    • Pre-insulated bundles need no heat source: say so and give the fluid temperature

    4. Area classification

    Only for electrical bundles in classified areas. The heating cable is the certified item; see the hazardous-area guide for how zones, gas groups and T-classes work.

    • Zone (or Class / Division) along the route
    • Gas group or dust group
    • Temperature class required (T1 to T6)
    • Certification scheme the project requires: IECEx, ATEX or another national scheme

    5. Insulation, jacket and environment

    Tube, insulation and outer jacket are built to the project requirement. Describe the site and any material rules, and we propose the construction.

    • Outdoor exposure: sunlight (UV), rain, marine or coastal air
    • Chemicals, oils or abrasion the jacket will meet
    • Jacket material rules in the project specification, for example flame-retardant or halogen-free
    • High process temperatures: fibre glass suits most duties; aerogel is used above 400 °C (752 °F)
    • Jacket colour or marking requirements, if any

    6. Lengths, ends and documents

    • Length of each bundle, and the number of bundles of each type
    • Supply form: continuous coil or straight lengths
    • How each end terminates: at the analyser, transmitter, sample probe or manifold
    • Accessories: end seals, entry seals, junction boxes
    • Documents the project requires with the supply, for example material certificates, test reports or data sheets
    • Delivery destination and the date you need the bundles on site

    How to send it

    Send the filled checklist, the project data sheet or a marked-up P&ID with the route lengths through the quote form or to sales@techwin.in. Partial data is fine: our engineers fill the gaps with you before the design is fixed.

    For a standard product you can also build the part number in the online configurator, and attach it to your request.

    Frequently asked questions

    What information is needed to quote a heat traced tubing bundle?

    The essentials are the number, size and material of the process tubes, the maintain and maximum exposure temperatures, the lowest ambient temperature, the heat source (electric supply voltage or steam pressure), the run lengths and, in classified areas, the zone, gas group and temperature class.

    What is the difference between maintain and exposure temperature?

    Maintain temperature is the temperature the fluid must be kept at or above. Maximum exposure temperature is the hottest the bundle will ever see, for example during steam-out. The heating cable and insulation must be chosen for both.

    Can I ask for a quote without complete data?

    Yes. Send what you have, such as a data sheet or a marked-up drawing. Techwin engineers agree the missing values with you before the bundle design is fixed.

    Ready to send your data?

    Send the checklist, a data sheet or a drawing with route lengths. Our engineers will review it and come back with a bundle proposal.